top of page

Shielded Personnel Tents

Rapid‑Deploy Shielded Workspace

For indoor & Outdoor use

When you need a fast, reliable and fully shielded workspace inside an existing room or shelter, our EMP‑ and RF‑protected personnel tent delivers a complete solution. Designed for rapid deployment, the tent creates a separate, isolated and signal‑blocked environment inside any indoor space—ready for use in 30–60 minutes, without special tools.

This certified structure is trusted by defence forces, emergency response units and critical civilian operations for short‑term missions where signal isolation, EMP protection and secure working conditions are essential.

 

Manufactured using  US made, RoHS compliant, conductive NOVA Select fabric and double (US No. 8,530,756) or single (US No. 9,029,714) patented door seal system in order to provide the highest shielding effectiveness for a RF / EMI shielded tent on the market.

 

Applications

  • Protected rooms, offices, shelters and civil defence bunkers

  • Crisis management and government operations

  • Military field deployments

  • Secure data workstations

  • Temporary shielded command rooms

Tent Options

  • 2‑person tent – approx. 1.8 × 1.8 × 2.2 m

  • 4‑person tent – approx. 2.6 × 2.6 × 2.2 m

  • Custom dimensions available for project‑specific needs → Ask about custom sizing

Technical Performance

Shielding

  • EMP & RF attenuation: average 90 dB

  • Full signal blocking across all common frequency ranges

  • Sound‑reducing inner lining

Construction

  • Self‑supporting, airtight tent structure

  • Zero‑threshold door for easy access

  • Flame‑resistant inner liner

  • Mechanically reinforced seams

I/O Filtered Feedthroughs

Pre‑installed filtered plates for secure connectivity:

  • AC/DC power

  • 1G & 10G Ethernet

  • USB

  • DB9 / DB25

  • HDMI 1.4

  • Additional interfaces available on request → Explore I/O customization

Equipment

  • EMP‑hardened lighting

  • Ventilation and exhaust channels

  • Optional accessories: window module, cabling kits, mounting points

Important Notes

  • Windowed model available

    • (Window version provides RF signal blocking but not full EMP protection)

  • If the shelter’s electrical system is not EMP‑protected, the tent requires a separate generator or protected power feed

  • Can be installed in any indoor space with sufficient floor area and ventilation

The manufacturer has contracted independent laboratories to perform the IEEE® 299 standard test on a complete assembled system including installed components operating under typical conditions at various frequencies measured through the tent wall at multiple locations in the tent.

Semi-permanent / permanent rectangular heavy-duty extruded aluminum frame (30-60minute deployment)

Tech sheet with more info here.

personell tent.png
bottom of page